If at the end of the day, the filtering pump operates for less time than
stipulated by the equipment for an optimum level of chlorine in the water, the
equipment will display a warning message.
4.2.4.7- Location of the swimming pool
Attention: This work mode only affects the semi-automatic operation
mode.
The swimming pool may be installed outdoors or indoors. Function changes
between INDOOR and OUTDOOR when the OK key is pressed.
With this function, the equipment automatically reduces production to ½ if it is
an indoor pool to avoid excess chlorine.
4.2.4.8- Cover
The equipment may detect the presence of a cover on the swimming pool
(only for automatic covers). In this case, it is only necessary to place the
limit switch of the cover in the terminal block, as indicated in the section on
electrical installation.
On placing the cover, the chlorinator automatically reduces production to 20%.
This variation will not be reflected in the production %, but the letter "C" will be
displayed on the right side of production in the main screen. This will indicate
that the cover is activated.
If chlorination is carried out with the cover in place, when it is
removed, the pool should not be used straightaway. It is
better to wait ½ hour for any vapours between the water and cover
to dissipate.