EN | Pizza Refrigerated Counters | User and Maintenance Manual
This manual and its contents remain the sole property of ELIWELL CONTROLS SRL, and shall not be reproduced or distributed without authorization
by ELIWELL CONTROLS SRL. Although great care has been exercised in the preparation of this document, ELIWELL CONTROLS SRL, its employees or
its vendors, cannot accept any liability whatsoever connected with its use. The same applies to any person or company involved in preparing and
editing this document. ELIWELL CONTROLS SRL reserves the right to make any changes or improvements without prior notice.
Permitted use
For safety reasons the instrument must be installed and used according to the instruction provided and in particular, under normal conditions, parts
bearing dangerous voltage levels must not be accessible. The device must be adequately protected from water and dust as per the application and
must also only be accessible via the use of tools (with the exception of the frontlet). The device is ideally suited for use on household appliances
and/or similar refrigeration equipment and has been tested with regard to the aspects concerning European reference standards on safety. It is
classified as follows:
• according to its manufacture: as an automatic electronic control device to be incorporated;
• according to its automatic operating features: as a 1 B-type operated control type;
• as a Class A device in relation to the category and structure of the software;
• device with pollution grade 2;
• as a device with class D fire resistance;
• overvoltage category grade II;
• device made with class IIIa material;
Unpermitted use
Any other use other than that permitted is de facto prohibited. It should be noted that the relay contacts provided are of a practical type and
therefore subject to fault. Any protection devices required by product standards or dictated by common sense due to obvious safety reasons should
be applied externally.
Mechanical Caracteristics
Front protection:
Housing:
Dimensions:
Mounting:
Terminals:
Connectors:
Temperature:
Humidity:
Electrical Caracteristics
Power Supply:
Consumption:
Display Range:
Accuracy:
Resolution:
Buzzer:
Analogue Input:
Digital Input:
Digital Output:
Regulations
Electromagnetic compatibility:
Security:
Food safety:
Classification:
NOTE 1: check the power supply specified on the instrument label; for relay, power supply capacities and PTC probes, contact the Sales
Office.
NOTE: The technical data included in this document, related to measurement (range, accuracy, resolution, etc.) refer to the instrument
itself, and not to its equipment such as, for example, sensors. This means, for example, that sensor(s) error(s) shall be added to the
instrument's one.
42
CONDITIONS OF USE
IP65.
PC+ABS UL94 V-0 resin plastic casing, polycarbonate glass, thermoplastic resin keys.
front 74x32 mm, depth 59 mm (excluding terminals).
panel mounting with 71x29 mm (+0.2/-0.1 mm) drilling template.
screw/removable terminals for cable with a diameter of 2,5mm
TTL for connection to Copy Card
Operating: -5 ... +55 °C - Storage: -30 ... +85 °C
Operating / Storage: 10...90 % RH (not condensing).
230Vac (+10% / -10%) 50/60 Hz
4.5W max
NTC: -50.0°C ... +110°C (on display with 3 digit + sign)
Better than 0,5% of full-scale + 1 digit.
0,1 °C.
YES (it depends from the model)
EW961: 1 NTC input. - EW971 and EW974: 2 NTC inputs.
1 voltage-free digital input
EW961: 1 Compressor relay: UL60730 (A) 1,5 Hp (10FLA - 60LRA) max 250Vac o
EW971: 1 Defrost relay:
1 Compressor relay: UL60730 (A) 1,5 Hp (10FLA - 60LRA) max 250Vac o
EW974: 1 Defrost relay:
1 Compressor relay: UL60730 (A) 1,5 Hp (10FLA - 60LRA) max 250Vac o
1 Fan relay:
This device complies with Directive 2004/108/EC and the harmonised standard EN 60730-2-9
This device complies with Directive 2006/95/EC and the harmonised standard EN 60730-2-9
This device complies with standard EN 13485 as follows:
- suitable for storage
- climate range A
- measurement class 1 in the range from -35°C to 25°C (*)
(* exclusively using Eliwell NTC probes)
operating (not safety) device for integration.
TABLE OF PARAMETERS
DISCLAIMER
TECHNICAL DATA
UL60730 (B)
2 Hp (12FLA - 72LRA) max 250Vac
N.O. 8(4)A - N.C. 6(3)A max 250Vac
UL60730 (B)
2 Hp (12FLA - 72LRA) max 250Vac
N.O. 8(4)A - N.C. 6(3)A max 250Vac
UL60730 (B)
2 Hp (12FLA - 72LRA) max 250Vac
5(2)A max 250Vac
2