CONNECTION OF THE POWER SUPPLY CABLE
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A" (fig.
8.1).
Unscrew the screw "D" and open completely the cable clamp "E" (figs. 8.2 - 8.3 - 8.4).
Position the U bolts "F" onto terminal board "G" (figs. 8.2 - 8.3 - 8.4) according to the
diagrams in fig. 8.5.
Connect the phase, neutral and earth wires to terminal board "G" according to the
diagrams in fig. 8.5.
Strain the feeder cable and block it with cable clamp "E" (by screwing screw "D").
Close the terminal block cover (check the two hooks "A" are correctly hooked).
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws fixing
the cover plate behind the terminal block.
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
Fig. 8.1
172
FEEDER CABLE SECTION
"TYPE H05RR-F or H05VV-F"
230 V ac
400 V 3N ac
400 V 2N ac
(**) Connection with wall box connection.
A
3 x 4 mm
5 x 2,5 mm
4 x 4 mm
Diversity factor applied.
A diversity factor may be applied to the
total loading of the appliance only by a
suitably qualified person.
2
(**)
2
(**)
2
(**)