Electrical Requirements; Remove Shipping Material - Kenmore 110.44422610 Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Stacked
12"
(305 mm)
12"
(305 mm)
3"
(76 mm)
1"
(25 mm)
Recessed area

Electrical Requirements

A 120-volt, 60 Hz., AC-only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is recommended that a separate circuit
serving only this appliance be provided.
This washer is equipped with a power supply cord having
a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be plugged
into a mating, 3 prong, grounding-type outlet, grounded in
accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and
obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate.
Do not ground to a gas pipe.
6
3"
(76 mm)
DRYER
48 in.
(310 cm
WASHER
24 in.
(155 cm
1"
3"
(25 mm)
(76 mm)
Closet door with vents
Check with a qualified electrician if you are not sure the
washer is properly grounded.
Do not have a fuse in the neutral or ground circuit.
2
2
)
2
2
)

Remove Shipping Material

Before you install your washer, remove all shipping material.
To avoid damaging floor, use a large flat piece of cardboard
from the washer carton. Place cardboard under entire back
of the washer.
Firmly grasp the body of the washer and gently lay it on the
corner posts.
Remove plastic foam packaging from underneath the washer.
Stand the washer up.
Remove tape from washer lid. Open washer lid and remove
foam shipping piece, parts bag, and hoses from washer basket.
Close the lid.

Publicité

Table des Matières
loading

Table des Matières