D15, D50, D52
Fault
Appliance switches itself
on and off
The light does not work
The appliance vibrates
The appliance seems to
make a lot of noise
The door does not close
properly
LED indicates EL or EH.
EN
Possible cause
Room temperature is higher than
average
The cabinet was recently replen-
ished with new bottles
Door was opened frequently
Door was not closed properly
Door is not hermetically sealed
The appliance is not connected
to a power supply
Circuit breaker or fuse has blown Switch on the circuit breaker;
The light was switched off on the
control panel
The appliance is not properly
level
The noise is probably caused by the refrigerant, which is nor-
mal. At the end of each cycle, you will hear noises made by the
flow of refrigerant.
If temperature fluctuations occur, the contraction and expansion
of the inner walls may cause popping and cracking noises
The appliance is not properly
level
The appliance is not properly
level
The door hinge was changed
incorrectly
The door seal is dirty
The shelves are not fitted cor-
rectly
The temperature sensor for the
air temperature inside the appli-
ance shows an error
Troubleshooting
Remedy
Put the appliance in a cooler
place
Leave the appliance to work
for a while until the set tem-
perature has been reached
Do not open the door more
often than necessary
Close door properly
Check the door seal and
clean or replace
Connect the appliance
switch on or replace the fuse
Switch on the light
Level out the appliance with
the adjustable feet
Level out the appliance with
the adjustable feet
Level out the appliance with
the adjustable feet
Check the door hinge and
reassemble correctly
Clean the door seal
Check the shelves and refit
correctly
This can only be repaired by
an authorised repair centre.
25