2.5.2. Configuration without network detection

It is also possible to configure the
in case the network settings are too restrictive and block the communication between the
software and RTCP09.
On the previous screen, click
"Manual configuration". A window
will prompt you to specify the IP
address as well as the number
of relay outputs in the concerned
RTCP09.
Click "Validate" to start the auto-
matic setup of Mozilla Sunbird.
The software configures Mozilla
Sunbird by associating it with the
previously selected RTCP09.
Mozilla Sunbird can now be used
to schedule the triggering of relay
outputs of the RTCP09.
Launch Mozilla Sunbird to start
configuring calendars.
82
RTCP09
without network detection. This can be useful