RX PW 1
7- Day Programming Cassette
1. Description
The programming cassette allows you to program for the
weekdays Monday to Friday as well as for the weekend, i.e.
Saturday to Sunday, up to 4 different time block in each case,
during which the heater is switched on. The programming
cassette can be used individually, i.e. for one heater, or
serially, i.e. for a group of heaters (e.g. for a complete dwelling
unit).
In the case of serial use, one heater is fitted with the
programming cassette. This unit is the so-called "master
control". After the electrical wiring (as shown in the installation
instructions of the heater) has been completed, all time
functions set on the master device will be transmitted to each
slave heater connected in series. The heating program preset
on the master device (time blocks for On/Off) will also be
executed on all slave heaters.
2. Installation
Turn off heater and
carefully tilt it toward the
front. With a flat-blade
screwdriver push
latching clip of cover in
the direction of the arrow
and remove cover. Slide
cassette all the way into
the opening.
3. Setting the Time an Day
Press the PROG button. The
"clock" symbol appears in the
upper left corner of the display
and the hours flash. Set the
hours using the ▼▲ buttons,
confirm with ENTER. Use the
same procedure to set the
minutes. Confirm with ENTER. .
The weekday indicator ►
flashes. Select the individual
weekdays using the ▼▲
buttons and confirm with ENTER.
M Monday
T Tuesday
F FridayS Saturday
S Sunday
4. Manual Switching On/Off Mode
Switch on the heater (indicator
lamp is illuminated). Press the
MODE button until MAN ON
appears on the display. The
device is switched on. If you
wish to switch the device off,
press MODE once more. The
display MAN OFF appears. The
device is switched off.
W Wednesday T Thursday
5. Automatic Mode
Switch on the heater. First, the weekdays Monday to Friday
are set. Press the PROG button twice. P1 ON appears on the
display and the hours flash. Set the hours using the ▼▲
buttons, confirm with ENTER. Use the same procedure to set
the minutes. Confirm with ENTER.
Note: Minutes can be set in 10-minute increments only!
P1 OFF now appears on the
display. Set the desired switch-
off time and confirm with
ENTER. Program P1 has thus
been set. P2 now appears, i.e.
another heater operating time
can be programmed. Programs
P3 and P4 can be set in the
same ma.nner. After the P4
OFF display has been con-
firmed, the program switches to
the setting mode for the two weekend days Saturday and
Sunday. The procedure for setting these time blocks is the
same as for the weekdays. The arrow on the right of the
display marks the currently selected day.To prematurely abort
the setting procedure, press the PROG button. All values
already set will be retained.
For the preset programs to be executed, the programming
cassette must be in the AUTO (automatic) mode. The
operating mode can be selected by means of the MODE
button.
6. Key Lock Setting
Successively press ENTER and
MODE. The buttons must be
pressed within 1 second. The
key symbol appears on the
display. All key functions are
locked. When the key com-
bination is pressed once more,
the keys are unlocked.
7. ADVANCE Mode
The ADVANCE mode enables the heater to provide instat
heat, i.e. before the preset
starting time.
Example: It is 2 p.m. A heater
operating time from 5 p.m. – 7
p.m. has been programmed, but
you want to start the heater
operation immediately. The
programmer is in the AUTO
mode. Press the ▲ button for 3
seconds. ADVANCE appears
on the display. The heater is now switched on and operates
until the end of the programmed time period (i.e. until 7 p.m.).
When the originally programmed starting time of the heater 
(5 p.m.) is reached, ADVANCE will disappear from the
display. 
The ADVANCE function can be manually cleared at any
time. Simply press the ▼ button..