Simu T3.5Hz02 Notice Originale page 7

Masquer les pouces Voir aussi pour T3.5Hz02:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
- Assembly:
ALUMINIUM WHEEL
Nm ≥ 60 & ALUMINIUM WHEEL
T6Hz02 : 9910062
2
Wiring
You must have the possibility to switch off individually each motor.
N
L
PE
230V ~ 50 Hz
- Attach cables to prevent any contact with moving parts.
- If the motor is used outdoors and if the power supply cable is of the H05-VVF type, then run the cable in a UV-resistant conduit,
e.g. trunking.
3
Compatible transmitters
1: 1/5 channels Wall Hz transmitter/ Memory Hz
2: 1/5 channels Mobile Hz transmitter
3: Color Multi 16 / Timer Easy / Timer Multi transmitters
4: Hz Sun sensor
Location of the PROG key on Hz transmitters:
Do not position the transmitter near metal in order to avoid
range losses.
4
End limit adjustment
If the installation includes several motors, only one motor is to be powered during this programming
procedure. It will eliminate interferences with the other motor during the procedure.
5
2
T5Hz02 : 9910004
5
2
5.3 Nm max
3
4
3
4
N
T3.5Hz02
L
PE
230V ~ 50 Hz
1
T5Hz02 - T6Hz02
(12 transmitters max. for one motor)
2
3
4
EN
2/5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

T5hz02T6hz02

Table des Matières