6
Programming a new (individual, group or main) control point:
6.1- Open the memory of the receiver from the control
transmitter:
- Press the PROG key of the transmitter for about 3 seconds.
The motor will run for 0,5 second in one direction, then in
the other.
6.2- Validate the operation from the new transmitter you
want to program:
- Press the PROG key of the transmitter for about 1 second.
The motor will run for 0,5 second in one direction, then in
the other.
- For group controls, repeat operations 6.1 and 6.2 for each motor in the group.
- For main controls, repeat operations 6.1 and 6.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 6.1 with a programmed transmitter, then
perform the operation 6.2 with the transmitter to be deleted.
7
Recording / controling / deleting intermediate position
Recording:
- Position the motor on the wanted
position.
- Press 5 seconds on the "STOP"
key. The motor will run for 0,5
second in one direction and then in
the other.
Deleting: Position the motor on the intermediate position. Press 5 seconds on the "STOP" key, the intermediate
position is deleted.
8
Re-adjustement of end limits
8.1- Re-adjustement of UP end limits:
1- Position the motor on the UP end limit previously set
in §4.3b with the "UP" key.
2- Press simultaneously for 5 seconds the "UP" and
"DOWN" keys, The motor will run for 0,5 second in
one direction and then in the other direction.
3- Adjust the new position with the "UP" and "DOWN"
keys.
4- Validate the new position by pressing 2 seconds the
"STOP" key. The motor will run for 0,5 second in one
direction and then in the other direction.
The new end limits setting is memorized.
8.2- Re-adjustement of DOWN end limits:
1- Position the motor on the DOWN end limit
previously set in §4.3a with the "DOWN" key.
2- Press simultaneously for 5 seconds the "UP" and
"DOWN" keys, The motor will run for 0,5 second in
one direction and then in the other direction.
3- Adjust the new position with the "UP" and
"DOWN" keys.
4- Validate the new position by pressing 2 seconds the
"STOP" key. The motor will run for 0,5 second in one
direction and then in the other direction.
The new end limits setting is memorized.
Controling: