Cooktop Use; Cooktop Controls - Whirlpool G7CG3064 Guide D'utilisation

Masquer les pouces Voir aussi pour G7CG3064:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NOTE: Burner ratings listed below are for Natural gas.
30" (76.2 cm) Model
A
D
A. Left rear surface burner (9,200 Btu/h)
B. Right rear surface burner (15,000 Btu/h)
C. Right front surface simmer burner (5,000 Btu/h)
D. Left front surface burner (17,000 Btu/h)
WARNING
Fire Hazard
Do not let the burner flame extend beyond the edge of
the pan.
Turn off all controls when not cooking.
Failure to follow these instructions can result in death
or fire.
IMPORTANT: Your cooktop is factory-set for use with Natural
Gas. If you wish to use LP Gas, an LP Gas Conversion Kit is
included with your new cooktop. See the instructions included
with the LP Gas Conversion Kit for details on making this
conversion.
4

COOKTOP USE

B
C

Cooktop Controls

Electric igniters automatically light the surface burners when
control knobs are turned on.
The large burners (17,000 Btu/h [British Thermal Units],
15,000 Btu/h and 12,500 Btu/h) provide the highest heat setting,
and are ideal for cooking large quantities of food or liquid, using
large pots and pans. The small burners (9,200 Btu/h, 9,000 Btu/h
and 5,000 Btu/h) allow more accurate simmer control at the
lowest setting, and are ideal for cooking smaller quantities of
food, using smaller pots and pans.
Before setting a control knob, place filled cookware on the grate.
Do not operate a burner while using empty cookware or without
any cookware on the grate.
NOTE: Visually check that the burner has lit. If the burner does
not ignite, listen for a clicking sound. If you do not hear the igniter
click, turn off the burner. Check for a tripped circuit breaker or
blown household fuse.
Proper grounding and polarity are necessary for correct operation
of the electric ignition system. If the wall receptacle does not
provide correct polarity, the igniters will become grounded and
occasionally click, even after the burner has ignited. Contact a
trained repair specialist to check the wall receptacle to see
whether it is wired with the correct polarity.
36" (91.4 cm) Model
A
B
E
A. Left rear surface simmer burner (5,000 Btu/h)
B. Center surface oval burner (9,000 Btu/h)
C. Right rear surface burner (12,500 Btu/h)
D. Right front surface simmer burner (5,000 Btu/h)
E. Left front surface flexible burner (17,000 Btu/h)
C
D

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

G7cg3665

Table des Matières