Manifold Pressure
Set the manifold pressure. There are two methods of manifold pressure regulation depending on the fi replace
model. Refer to diagrams below to determine appropriate method.
Early Models
(with separate regulator)
1. Remove the regulator cap with a wrench.
2. Pull the plastic pin out of the cap, invert it and push it
back into the cap.
3. Refi t the cap back on the regulator.
NG
6
Shut-off valve
supplied with
fi replace
Flex pipe
supplied with
fi replace
Separate
convertible
regulator
No regulator in
control valve
1. Fit a manometer to the manifold pressure test tap on
2. Light the appliance and turn the control to full input.
3. Check for leaks downstream of the valve. Adjust the
LPG
Later Models
(with integral regulator)
Shut-off valve
supplied with
fi replace
Flex pipe
supplied with
fi replace
Control valve
with integral
regulator
the valve—see fi gure below.
pressure adjustment screw using a small jeweller's
size fl at blade screwdriver—as shown below—while
the appliance is running at full input to produce
manifold pressure, as per Specifi cations chart on
page 1.
Loosen screw to check
(tighten afterwards)
Manifold Pressure
Test Tap
Valve Inlet
Pressure
Pressure Test Tappings
Front Face of
Control Valve
Pry off
plastic cap
Front Face of
Control Valve
Pressure
adjustment
screw behind
plastic cap
Increases pressure
Decreases pressure