14
24
15
FAST-BLOW FUSE,
5 AMP
PLACING THE GREASE BUCKET
PARTS REQUIRED:
1
x
Grease Bucket (#24)
INSTALLATION:
Place the grease bucket on the spout hook on the bottom of the main barrel.
Ensure it is level to avoid grease spills.
The unit is now completely assembled.
CONNECTING TO A POWER SOURCE
STANDARD OUTLET
This unit requires 110 volt, 60 Hz, 375 W, 5 amp service. It must be a 3-prong
grounded plug. Ensure grounded end is not broken off. The control uses a 5 amp,
120 volt, fast-blow fuse to protect the board from the igniter.
GFCI OUTLETS
This unit works on most GFCI outlets, with a recommended size of 15 amp service.
If the GFCI outlet is highly sensitive to power surges, it will likely trip during the
start-up phase of operation. During the start-up phase, the igniter draws 300-700
watts of electricity which can be too much power for a GFCI outlet to handle. Each
time the GFCI trips, it increases in sensitivity. If the GFCI keeps tripping, replace the
outlet or change to a non-GFCI outlet.
ON THE ROAD
Disconnect the igniter from the main wiring harness. Use the manual start-up
procedure. The unit can operate using a 12 volt, 100 watt positive wave length
inverter plugged into your automobile outlet. To use the automatic igniter, it is
recommended to use a minimum of a 1000 watt positive wave length inverter.
IMPORTANT: DISCONNECT UNIT FROM POWER SOURCE WHEN NOT IN USE.
www.vermontcastingsbbq.com