Télécharger Imprimer la page
Masquer les pouces Voir aussi pour 5202B:

Publicité

Liens rapides

Isolation
Galvanic isolators for analogue and digital
signals as well as HART
®
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Displays
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume, weight, etc. Feature linearisation, scaling, and
difference measurement functions for programming via
PReset software.
Ex barriers
Interfaces for analogue and digital signals
as well as HART
®
signals between sensors / I/P convert-
ers / frequency signals and control systems in Ex zone 0,
1 & 2. Feature options such as mathematical functions
and 2 wire transmitter interfaces.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Backplane
Flexible motherboard solutions for sys-
tem 5000 modules. Our backplane range features fl exible
8 and 16 module solutions with confi guration via PReplan
8470 – a PC program with drop-down menus.
All manuals and user guides at all-guides.com
5 2 0 2 B
P u l s e I s o l a t o r
N o . 5 2 0 2 B V 1 0 6 - I N ( 0 3 2 4 )
F r o m s e r . n o . 0 2 0 2 5 2 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 17
UK
Page 33
FR
Seite 49
DE

Publicité

loading

Sommaire des Matières pour PR electronics 5202B

  • Page 1 All manuals and user guides at all-guides.com Isolation Galvanic isolators for analogue and digital signals as well as HART ® signals. A wide product range with both loop-powered and universal isolators featuring linearisation, inversion, and scaling of output signals. Displays Programmable displays with a wide se- lection of inputs and outputs for display of temperature, volume, weight, etc.
  • Page 2 All manuals and user guides at all-guides.com IMPULSISOLATOR PRecon 5202B Indholdsfortegnelse Advarsler ................Sikkerhedsregler..............Overensstemmelseserklæring ..........Adskillelse af SYSTEM 5000..........Anvendelse................. Teknisk karakteristik ............Montage / installation............Applikationer ..............Bestillingsskema..............Elektriske specifikationer ........... Jumperprogrammering............12 Funktionsbeskrivelse............13 Blokdiagram 5202B1 og -B2 ..........14 Blokdiagram 5202B4............
  • Page 3 Reparation af modulet og udskiftning af sikringer må kun MODTAGELSE OG UDPAKNING: foretages af PR electronics A/S. Udpak modulet uden at beskadige dette, og sørg for, at manualen altid følger modulet og er tilgængelig. Indpakningen bør følge modulet, indtil dette er mon- teret på...
  • Page 4 PR electronics A/S den lokale forhandler eller alternativt direkte til: Lerbakken 10 PR electronics A/S, Lerbakken 10, 8410 Rønde, Danmark tlf: +45 86 37 26 77. Installation og tilslutning af modulet skal følge landets gældende regler for DK-8410 Rønde installation af elektrisk materiel bl.a. med hensyn til ledningstværsnit, for-sikring hermed at følgende produkt:...
  • Page 5 All manuals and user guides at all-guides.com ADSKILLELSE AF SYSTEM 5000 IMPULSISOLATOR Husk først at demontere tilslutningsklemmerne med farlig spænding. PRecon 5202B Billede 1: Modulet frigøres fra DIN-skinnen ved at løfte i den nederste lås. • 2 kanaler - 2 eller 4 udgange •...
  • Page 6 All manuals and user guides at all-guides.com Elektriske specifikationer: Specifikationsområde: -20°C til +60°C Fælles specifikationer: Forsyningsspænding universel....24...230 VAC ±10% 50...60 Hz 24...250 VDC ±20% Egetforbrug, 5202B1 og -B2 ...... ≤ 1,5 W (2 kanaler) Max. forbrug, 5202B1 og -B2 ..... ≤ 1,5 W (2 kanaler) Egetforbrug, 5202B4 ........
  • Page 7 All manuals and user guides at all-guides.com Indgange: Overholdte myndighedskrav: Standard: Følertyper: EMC 89/336/EØF, Emission ....... EN 50 081-1, EN 50 081-2 NAMUR i henhold til ....... EN 60 947-5-6 Immunitet...... EN 50 082-2, EN 50 082-1 Mekanisk kontakt Emission og immunitet...... EN 61 326 Frekvensområde..........
  • Page 8 All manuals and user guides at all-guides.com Jumperprogrammering: Funktionsbeskrivelse: Forbindelseseksempler på blokdiagram (1)...(4) (1) NAMUR-føler med kabelfejlsdetektering for brud og kortslutning. (2) Mekanisk kontakt med kabelfejlsdetektering for brud og kortslutning, når Rs og Rp er monteret på kontakten. (3) Mekanisk kontakt med kabelfejlsdetektering for brud, når Rp er monteret på kontakten.
  • Page 9 All manuals and user guides at all-guides.com BLOKDIAGRAM: 5202B1 OG -B2 BLOKDIAGRAM: 5202B4...
  • Page 10 All manuals and user guides at all-guides.com PULSE ISOLATOR PRecon 5202B Contents Warnings ................18 Safety instructions.............. 19 Declaration of Conformity ..........21 How to dismantle SYSTEM 5000........22 Application ................. 23 Technical characteristics ............ 23 Mounting / installation............23 Applications................
  • Page 11 Repair of the module and replacement of circuit breakers the module until this has been permanently mounted. must be done by PR electronics A/S only. Check at the receipt of the module whether the type corresponds to the one ordered.
  • Page 12 Lerbakken 10 contact your local distributor or, alternatively, DK-8410 Rønde PR electronics A/S, Lerbakken 10, 8410 Rønde, Danmark tlf: +45 86 37 26 77. hereby declares that the following product: Mounting and connection of the module should comply with national legislation for mounting of electric materials, i.a.
  • Page 13 All manuals and user guides at all-guides.com HOW TO DISMANTLE SYSTEM 5000 PULSE ISOLATOR First, remember to demount the connectors with hazardous voltages. PRecon 5202B Picture 1: By lifting the bottom lock, the module is detached from the DIN rail.
  • Page 14 All manuals and user guides at all-guides.com Electrical specifications: Specifications range: -20 to +60°C Common specifications: Supply voltage universal ......24...230 VAC ±10% 50...60 Hz 24...250 VDC ±20% Internal consumption, 5202B1 and 5202B2 . ≤ 1.5 W (2 channels) Max. consumption, 5202B1 and 5202B2 ... ≤ 1.5 W (2 channels) Internal consumption, 5202B4 .....
  • Page 15 All manuals and user guides at all-guides.com Inputs: Observed authority requirements: Standard: Sensor types: EMC 89/336/EEC, Emission ....... EN 50 081-1, EN 50 081-2 NAMUR acc. to........EN 60 947-5-6 Immunity ....... EN 50 082-2, EN 50 082-1 Mechanical contact Emission and immunity .......
  • Page 16 All manuals and user guides at all-guides.com Jumper programming: Function description: Examples of connections on block diagram (1)...(4) (1) NAMUR sensor with cable error detection in case of cable disconnection or short-circuit. (2) Mechanical contact with cable error detection in case of cable disconnection or short-circuit, when Rs and Rp are mounted on the contact.
  • Page 17 All manuals and user guides at all-guides.com BLOCK DIAGRAM: 5202B1 AND 5202B2 BLOCK DIAGRAM: 5202B4...
  • Page 18 All manuals and user guides at all-guides.com ISOLATEUR D’IMPULSIONS PRecon 5202B Sommaire Avertissements ..............34 Consignes de sécurité ............35 Déclaration de conformité..........37 Démontage du SYSTEME 5000......... 38 Application ................. 39 Caractéristiques techniques ..........39 Montage / installation............39 Applications................
  • Page 19 RECEPTION ET DEBALLAGE : Seule PR electronics SARL est autorisée à réparer le module Déballez le module sans l’endommager. Le guide doit toujours être disponible et et à remplacer les dis joncteurs.
  • Page 20 PR electronics SARL, Zac du Chêne, Activillage, 2, allée des Sorbiers, F- déclare que le produit suivant : 69500 Bron (tél. : (0) 472 140 607) ou à PR electronics A/S, Lerbakken 10, Type : 5202B DK-8410 Rønde, Danemark (tél. : +45 86 37 26 77).
  • Page 21 All manuals and user guides at all-guides.com DEMONTAGE DU SYSTEME 5000 ISOLATEUR D’IMPULSIONS Tout d’abord, n’oubliez pas de démonter les connecteurs où règnent des ten- PRecon 5202B sions dangereuses. Figure 1 : Débloquez le verrou inférieur pour dégager le module du rail DIN.
  • Page 22 All manuals and user guides at all-guides.com Spécifications électriques : Plage des spécifications : -20 à +60°C Spécifications communes : Tension d’alimentation universelle ....24...230 Vca ±10% 50...60 Hz 24...250 Vcc ±20% Consommation interne, 5202B1 et 5202B2.. ≤ 1,5 W (2 voies) Consommation max., 5202B1 et 5202B2...
  • Page 23 All manuals and user guides at all-guides.com Entrées : Agréments et homologations : Standard : Types de capteurs : CEM 89/336/CEE, Emission ....... EN 50 081-1, EN 50 081-2 NAMUR suivant ........EN 60 947-5-6 Immunité ....... EN 50 082-2, EN 50 082-1 Contact mécanique Emission et immunité...
  • Page 24 All manuals and user guides at all-guides.com Programmation des cavaliers : Déscription des fonctions : Exemples de connexions du schéma de principe (1)...(4) : (1) Capteur NAMUR avec la détection de ruptures et court-circuits. (2) Contact mécanique avec la détection de ruptures et court-circuits, quand le Rs et le Rp sont montés sur le contact.
  • Page 25 All manuals and user guides at all-guides.com SCHEMA DE PRINCIPE : 5202B1 ET 5202B2 SCHEMA DE PRINCIPE : 5202B4...
  • Page 26 All manuals and user guides at all-guides.com IMPULSISOLATOR PRecon 5202B Inhaltsverzeichnis Warnung ................50 Sicherheitsregeln..............51 Konformitätserklärung............53 Zerlegung des Systems 5000 ..........54 Verwendung................ 55 Technische Merkmale............55 Montage / Installation............55 Anwendungen ..............56 Bestellangaben..............57 Elektrische Daten ............... 57 Überbrücker Programmierung ...........
  • Page 27 Reparaturen des Moduls und Austausch von Sicherungen EMPFANG UND AUSPACKEN: dürfen nur von PR electronics A/S vorgenommen werden. Packen Sie das Modul aus, ohne es zu beschädigen und sorgen Sie dafür, dass das Handbuch stets in der Nähe des Moduls und zugänglich ist.
  • Page 28 DK-8410 Rønde direkt mit PR electronics GmbH, Bamlerstraße 92, D-45141 Essen, (Tel.: (0) 201 860 6660) oder mit PR electronics A/S, Lerbakken 10, DK-8410 Rønde, hiermit für das folgende Produkt: Dänemark (Tel. : +45 86 37 26 77) Kontakt aufnehmen.
  • Page 29 All manuals and user guides at all-guides.com ZERLEGUNG DES SYSTEMS 5000 IMPULSISOLATOR Zunächst ist gefährliche Spannung von den Anschlussklemmen zu trennen. PRecon 5202B Abbildung 1: Das Modul wird von der DIN- Schiene gelöst, indem man den • 2-kanalig - 2 oder 4 Ausgänge unteren Verschluss löst.
  • Page 30 All manuals and user guides at all-guides.com Elektrische Daten: Spezifikationsbereich: -20 bis +60°C Allgemeine Daten: Versorgungsspannung universell ....24...230 VAC ±10% 50...60 Hz 24...250 VDC ±20% Eigenverbrauch, 5202B1 und 5202B2 ..≤ 1,5 W (2 Kanäle) Max. Verbrauch, 5202B1 und 5202B2..≤ 1,5 W (2 Kanäle) Eigenverbrauch, 5202B4......
  • Page 31 All manuals and user guides at all-guides.com Eingänge: Eingehaltene Behördenvorschriften: Norm: Sensortypen: EMV 89/336/EWG, Emission ...... EN 50 081-1, EN 50 081-2 NAMUR gemäß ........EN 60 947-5-6 Immunität ....EN 50 082-2, EN 50 082-1 Mechanischer Schalter Emission und Immunität ....EN 61 326 Frequenzbereich..........
  • Page 32 All manuals and user guides at all-guides.com Überbrücker Programmierung: Funktionsbeschreibung: Verbindungsbeispiele auf Blockdiagramm (1)...(4) (1) NAMUR-Sensor mit Kabelfehlererkennung für Bruch und Kurzschluss. (2) Mechanischer Schalter mit Kabelfehlererkennung für Bruch und Kurzschluss, wenn Rs und Rp auf dem Schalter montiert ist. (3) Mechanischer Schalter mit Kabelfehlererkennung für Bruch, wenn Rp auf dem Schalter montiert ist (4) Mechanischer Schalter ohne Kabelfehlererkennung.
  • Page 33 All manuals and user guides at all-guides.com BLOCKDIAGRAMM: 5202B1 UND 5202B2 BLOCKDIAGRAMM: 5202B4...
  • Page 34 All manuals and user guides at all-guides.com...
  • Page 35 All manuals and user guides at all-guides.com Head offi ce PR electronics A/S tilbyder et bredt program af analoge og di- Denmark www.prelectronics.com gitale signalbehandlingsmoduler til industriel automation. Vores PR electronics A/S sales@prelectronics.dk Lerbakken 10 tel. +45 86 37 26 77 kompetenceområder omfatter: Isolation, Displays, Ex-barrierer,...