Noticed a too
high
temperature of
Safety
the boiler
Thermal
(it is necessary
to reset
manually the
back thermostat
Press
Noticed wrong
Water
boiler pressure.
Boiler temperat.
Feeler
feeler signaling
Water
error.
Feeler
Exhaust feeler
exhaust
signaling error
Fume
Hot
temperature too
exhaust
high
Boiler water
Hot
temperature too
Water
high
A black-out has
happened during
Black-Out
the regular
working.
EXAMPLES OF APPLIANCE/PLANT CONNECTION
The following connection diagrams are only indications of some connection
possibilities and should not be considered as satisfaction in matter of installations.
Breakdown/block plant
circulation pump.
Breakdown bulb security
boiler temperature feeler
Air inside the boiler
Wrong pressure of thermal
plant.
Too high pressure
Electrical connections
interrupted.
Pressure switch control
breakdown.
Wrong appliance
carburation.
Change fuel.
Fume feeler
Wrong appliance
carburation
Breakdown/block
circulation plant pump.
Air inside the boiler.
Fume feeler.
74/120
IT IT IT IT- - - - GB
GB- - - - FR
FR mod. Serie 698TP....
GB
GB
FR
FR
Check circulation pump working.
Verify/replace thermostat, verify
wiring .
Eliminate air from the thermal plant.
Verify thermal plant pressure.
(min. 0,5bar max. 2bar).
Reduce the pressure of the plant by
draining water.
Verify the electrical connections of
pressure switch.
Verify/replace pressure switch
control.
Verify/replace temperature feeler.
Verify/replace exhaust feeler.
Verification of appliance by a
technical service center.
Proceed with "Pellet Correct".
Verification of appliance by a
technical service center.
Utilize better quality of pellet .
Proceed with "Pellet Correct".
Verify fume feeler position.
Verify/replace fume feeler.
Verification of appliance by a
technical service center.
Proceed with "Pellet Correct".
Verify circulation pump working
Eliminate air from the thermal plant
Verify boiler feeler position.
Verify/replace boiler feeler.
Empty and clean the burner basket
and then proceed with the lighting
phase.