Any repairs must be carried out by an authorized after-sales service or
qualified staff.
Attention: Disconnect always the appliance before making any interventation.
CORISIT S.r.l. is not responsible for damages to thing or people due to a wrong installation,
equipment tampering, improper use, bad maintenance or no observation of normative in
force. If considerate appropriate, CORISIT S.r.l. reserves the right to make modifications
without notice and in every moment.
Some particulars and accessories illustrated in this handbook are not mass produced item so
its extra costs are to check at contract release.
Alarm indications on display
Alarm
Explication
In the starting
phase the
No lighting
lighting of fuel
failed or fire has
not been noticed
Fume expeller
Fan
motor is
Lightin
breakdown
No fire is noted
Error
in the burner
Fire
basket
Fume exhaust
Failure
duct clogged
Depress
Probable cause
No pellets feed
Lighting element broken
Fume feeler has not noticed
fire
Difficulties to light the
pellets
Someting is blocking the
fume motor
Electrical connections
interrupted
Breakdown motor
No pellet feeding
Fume feeler
Chimney clogged.
Electrical connections
interrpted.
Breakdown pressure switch
73/120
IT IT IT IT- - - - GB
GB- - - - FR
FR mod. Serie 698TP....
GB
GB
FR
FR
Cure
Check if there is pellet into the
container
Check operating of screw feeder
Check electrical wiring.
Replace lighting element.
Verify the position, operating and
electrical connection of fume
temperature feeler.
Utilize better quality of pellets
Check fume exhaust duct.
Check electrical connection of the
motor and revolotion counter
(encoder).
Replace motor.
Verify pellet available in container
Verify screw feeder operating
Verify stoppage/clogging screw
feeder.
Verify electrical wire.
Verify the position of fume feeler.
Verify/replace fume feeler.
Verify chimney.
Verify integrity electrical connections
of pressure switch.
Replace pressure switch