Make Electrical Connection - Jenn-Air JXW9036WP Instructions D'installation Et Guide D'utilisation Et D'entretien

Hotte de cuisinière pour montage mural 30", 36" et 48" (76,2 cm, 91,4 cm et 121,9 cm)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Attach power cord connector to connector on wire box on
blower motor mounting plate.
B
C
A. Blower motor mounting plate
B. Wire box connector
C. Power cord

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Locate junction box inside of the range hood.
A. Terminal box cover
B. Knockout in canopy
back into terminal box
10
A
B
A
A
B
C
D
A. White wires
B. Black wires
C. UL listed wire connectors
D. Green, Bare or Yellow/Green wires
E. Home power supply
F. UL listed or CSA approved ¹⁄₂" strain relief
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Use UL listed wire connectors and connect white wires (A)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
5. Connect green (or bare) ground wire from home power supply
to the green/yellow ground wire (C) in terminal box using UL
listed wire connectors.
6. Install terminal box cover.
7. Check all light bulbs to make sure they are secure in their
sockets.
8. Reconnect power.
E