Model(s): 2357 • 2357CA
HOW TO TURN ON THE GAS:
Turn the hand wheel counter-
clockwise 1 to 3 turns�
LEAK TEST INSTRUCTIONS
• leak test new and exchanged lPG cylinders BeFoRe connecting to
appliance�
• do NoT smoke during leak test�
• do NoT use an open flame to check for gas leaks�
• Appliance must be leak tested outdoors in a well-ventilated
area, away from ignition sources such as gas fired or electrical
appliances�
• during leak test, keep appliance away from open flames or sparks�
Turn oFF the gas supply at the gas cylinder valve� ensure that
STEP 01
the controls are oFF�
Connect the regulator to the lPG cylinder and turn oN the gas�
If you hear a rushing sound, turn gas off immediately. There is a major leak at
If you hear a rushing sound, turn gas off immediately. There is a major leak at
the connection.
the connection.
Make a leak detecting
STEP 02
solution by mixing 15 ml
(one tbsp) of hand/ dish soap
with 60 ml (1/4 cup) of water�
Use a clean paintbrush
STEP 03
to brush the leak detecting solu-
tion onto joint areas of valves
and regulator�
If leaks are detected
STEP 04
(indicated by growing bubbles),
immediately turn oFF the gas
and re-tighten connections�
WARNING
⚠
If leaks cannot be stopped,
DO NOT try to repair.
Regulator must be replaced
with a Blackstone approved
model by a professionally
licensed, authorized dealer.
BLACKSTONE PRODUCTS
OPERATION INSTRUCTIONS
EXCHANGING THE GAS CYLINDER
• Use only those reputable exchange companies that inspect, preci-
sion fill, test and certify their cylinders� lPG dealer must purge new
cylinder before filling�
• To remove gas from lPG cylinder, contact a certified lPG dealer or
local fire department for assistance�
• do NoT release liquid petroleum gas (lPG) into the atmosphere�
Your retailer can help you match a replacement lPG cylinder to your appliance.
Your retailer can help you match a replacement lPG cylinder to your appliance.
Volume of propane in cylinder will vary by temperature.
Volume of propane in cylinder will vary by temperature.
⚠
A frosty regulator indicates gas overfill. Immediately close
LPG cylinder valve and call local LPG dealer for assistance.
• exchange cylinder only for an oPd safety feature-equipped
cylinder�
STORING LPG CYLINDERS
⚠
• DO NOT store a spare LPG cylinder under, near, or in this
appliance.
• DO NOT fill an LPG cylinder beyond 80% full.
If the information above is not followed exactly, a fire causing
death or serious injury may occur.
• The lPG cylinder must be turned oFF when the appliance is
not in use�
• lPG cylinders must be stored outdoors and out of the reach
of children�
• do NoT store an lPG cylinder inside a building, garage, or in any
other enclosed area�
• do NoT store an lPG cylinder where temperatures can reach over
122°F (50°C)�
DISCONNECTING THE LPG CYLINDER
storage of the appliance indoors is only permissible if the lPG cylinder is
storage of the appliance indoors is only permissible if the lPG cylinder is
disconnected and removed from the appliance.
disconnected and removed from the appliance.
ensure that the control knobs are
turned to oFF�
❶ ❶ ensure that the lPG cylinder
is oFF by turning the hand wheel
clockwise to a full stop�
❷ ❷ Turn the coupling nut count-
er-clockwise by hand to remove
the regulator� (do NoT use tools
to disconnect�)
Place dust cap on cylinder valve outlet whenever the cylinder is not in use. only
Place dust cap on cylinder valve outlet whenever the cylinder is not in use. only
install the type of dust cap on the cylinder valve outlet that is provided with the
install the type of dust cap on the cylinder valve outlet that is provided with the
cylinder valve. other types of caps or plugs may result in leakage of propane.
cylinder valve. other types of caps or plugs may result in leakage of propane.
| OWNER'S MANUAL
WARNING
WARNING
❶ ❶
❷ ❷
15