SYSTÈME D'ÉVACUATION DU FOYER – PAR LE HAUT
Aucun coude
DIMENSIONS
MINIMUM
10 pi
Three Elbows
NOTICE: Subtract 3 feet from the total horizontal measurement
for each 90° elbow installed horizontally. Subtract 1-1/2 feet from
the total horizontal measurement for each 45° elbow installed
horizontally.
A
JUSQU'AU BAS
B
DE L'APPAREIL
EXEMPLES DE LONGUEURS DE CONDUITS
LONGUEUR
INITIALE DU
A (Verticale)
CONDUIT
36 po
48 po
8 pi
21 pi
41359-3-1024
SORTIE VERTICALE
MAXIMUM
40 pi
Figure 45
INSTALLÉ
VERTICALEMENT
B (Horizontale
Maximale)
6 pi
7 pi, 4 po
7 pi
12 pi
12 pi
14 pi, 8 po
25 pi
7 pi
Figure 46