2. Safety
The manufacturer shall not be liable for claims of any type based on operation
contrary to the intended use.
2.2 Responsibility of the operator
EN
The legibility of the marking must be observed during time in use but at least
during inspection periods of three years. If any harm of the legibility is found
please contact the manufacturer to renew the marking.
For the safety of the system, the operator is obliged to carry out an ignition source
and ignition hazard analysis. Refer to chapter 2.3 "Ignition hazards".
The responsibility for classification of zones lies with the plant manager and not
the manufacturer/supplier of the equipment.
2.3 Ignition hazards
Relevant identified ignition
hazards
Hot surfaces
Mechanically generated sparks
and hot surfaces
Stray electric currents, cathodic
corrosion protection
Static electricity
Exothermic reactions, including
self-ignition of dusts
6
Implemented protective measures
The actual surface temperature depends on the
■
application, i.e. on the medium temperature
Temperature range marking; T range marking
■
Observation of legibility of marking
■
▶
Information given in operating instructions
Low contact speed
■
Restriction of vibration
■
Selection of suitable materials
■
▶
Information given in operating instructions
Grounding via process connection required
■
▶
Information given in operating instructions
No propagating brush discharge
■
All conductive parts bonded
■
Limitation of projected area of non-conductive
■
parts
Limitation of layer thickness of non-conductive
■
parts
Grounding via process connection required
■
Description of cleaning process
■
▶
Information given in operating instructions
Provision of material data of the wetted parts for
■
the customer in order to avoid the use of critical
media
▶
Information given in operating instructions
WIKA operating instructions pressure gauge model 7 per ATEX