8020347.1MMD/2024-07-19 | SICK
Subject to change without notice
WTS16G-xxxxx9xx, red light:
Minimum distance in mm (y) between the set sensing
range (x) and white background (90 % remission)
y
80
(3.15)
60
(2.36)
40
(1.57)
90 %/90 %
20
(0.79)
0
0
100
200
(3.94)
(7.87)
Recommended sensing range for the best
performance
Figure 9: Characteristic curve
Black object, 6% remission factor
1
Gray object, 18% remission factor
2
White object, 90% remission factor
3
blue
Recommended sensing range for the best performance
Example:
Safe suppression of the background
1
6 %/90 %
2
18 %/90 %
3
Black object (6 % remission)
Set sensing range x = 300 mm
Needed minimum distance to white
x
background y = 20 mm
300
400
(11.81)
(15.75)
Distance in mm (inch)
O P E R A T I N G I N S T R U C T I O N S | WTL16 / WTS16
OPERATING INSTRUCTIONS
White
background (90 %)
x
y
en
41