NOTES ON LOCATIONS
1. Place the outdoor unit on a stable base.
2. Secure sufficient space around the unit for ventilation.
3. The unit should neither be exposed to strong wind nor splash from rain water.
4. Ensure that the drain water is properly drained. Since water will flow from the
drain of the outdoor unit, do not place anything under the unit which must
be kept away from moisture. Lay a drain hose if required. In cold regions,
installation of the drain hose is not recommended as it could be frozen.
5. Keep TV set, radio and alike at least 39.4 inches (1 m) away from the indoor unit.
6. Avoid locations exposed to machine oil vapor, salty air (facing the seashore,
ACCESSORIES
ITEMS
Q'ty
1 Manual
1
PIPING
Max. total piping length
Max. piping length: A
of all unit
82 ft (25 m)
3 units: 230 ft (70 m)
• Standard piping length is 25 ft (7.6m).
• When the outdoor unit is placed at a higher level than the indoor unit, provide a trap near the hose's lead-in port.
Use the refrigerant pipes shown in the table below.
Pipe size
Liquid side
1/4" (6.35 mm)
Gas side
3/8" (9.52 mm)
• The thermal insulation should cover both the gas and liquid pipes.
PORT SIZE OF THE OUTDOOR UNIT
Install the indoor unit according to the following table.
Port
Port size
Liquid
A
Gas
Liquid
B
Gas
Liquid
C
Gas
1
OUTDOOR UNIT INSTALLATION
Before installation,
remove the packing pad
from the outdoor unit.
INSTALLATION DIAGRAM
Provide as much installation space as
possible for efficient air-conditioning.
Caution:
In the area with heavy snowfall, keep at least
10 inches distance between outdoor unit and
ground and / or snow. Avoid snow blocking the
outlet of the outdoor unit. During defrosting
the drain holes in the outdoor unit pan should
always be free and let the water flow thru, if
there is snow blocking the flow of water the
ice will accumulate and damage the unit.
Min. piping length: A
10 ft (3 m)
(15 m)
Piping Thickness
0.03 in.
Thickness: 0.24 in. (6 mm) or thicker
(0.8 mm)
Material: Polyethylene foam
1/4" (ø 6.35 mm)
9,000/12,000/18,000 Btu/h
3/8" (ø 9.52 mm)
1/4" (ø 6.35 mm)
9,000/12,000/18,000 Btu/h
3/8" (ø 9.52 mm)
1/4" (ø 6.35 mm)
9,000/12,000/18,000 Btu/h
3/8" (ø 9.52 mm)
Packing pad
for example), hot spring vapor sulfur gas, muddy water (along a road, for
example), etc. Such substances can cause malfunction of the unit. Also avoid
locations where the unit can be tampered with.
7. Select a location where neither the outgoing air or operating noise annoy
others.
8. Keep the air outlet opening free of any obstacle. This could affect the
performance of the unit and create loud noises.
9. In cold climate area, place outdoor unit at a location not affected by snowfall
or ice (below roof slope of houses, for example). The unit must be installed at
least 10 inches (254mm) above the average snow accumulation in the area.
12 in.
(300 mm)
40 in.
(1000 mm)
10 in. (254 mm)
clearance above snow
buildup at all times.
Max. height difference:
Chargeless Max. piping
B
C
D
49 ft
49 ft
33 ft
98 ft (30 m)
(15 m)
(10 m)
Thermal insulation
Indoor unit class
Installation dimension
Referring to the figure, firmly fasten the outdoor
unit with bolts.
A
EN-2
12 in.
(300 mm)
Coating tape
(Commercially available)
16 in.
(400 mm)
Additional refrigerant
length
0.11 oz/ft (10 g/m)
B
D
Note:
• Be sure to install 2 or 3 indoor units.
A
21.9 in.
14.6 in.
B
(557 mm)
(370 mm)
Cable cover
Piping cover
A
C
Trap
B