Télécharger Imprimer la page

HOLZMANN MASCHINEN BBS550SMART 400V Mode D'emploi page 43

Publicité

14.3
Electrical connection
Dangerous electrical voltage!
 The machine may only be connected to the mains supply and the associated
checks carried out by a qualified electrician or under the instruction and
supervision of a qualified electrician!
Check, whether the neutral connection (if existing) and the protective grounding function
properly.
Check, whether the supply voltage and the frequency correspond to the specifications of
the machine.
Deviation of the supply voltage and frequency!
A deviation from the value of the supply voltage of ±5 % is permissible.
A short-circuit fuse must be provided in the power supply system of the machine!
Use a supply cable of type H07RN (WDE282) and take the required cross-section of the
supply cable from a current carrying capacity table. Pay attention to the measures for
protection against mechanical damage.
Make sure that the power supply is protected by a residual current circuit breaker.
Connect the device only to a properly grounded outlet.
When using an extension cable, make sure that the dimension matches the connected
load of the machine. The connection power can be found in the technical data, the
correlation of cable cross-section and cable lengths can be found in the technical literature
or obtain information from a specialist electrician.
A damaged cable must be replaced immediately.
Setting up a 400 V machine
The grounding conductor is yellow-green.
Connect the supply cable to the corresponding terminals in the input box (L1, L2, L3, N and
PE). If a CEE plug is available, the connection to the mains is made through an
appropriately powered CEE coupling (L1, L2, L3, N and PE).
Plug connection 400V:
After the electrical connection, check the correct running direction. If the machine runs in
the wrong direction, swap two conductive phases, egg. L1 and L2, at the connection plug.
-
Operation is only permitted with residual current device (RCD) with maximum
residual current of 30 mA.
HOLZMANN Maschinen GmbH
WAR N I N G
5-wire:
with
N-conductor
www.holzmann-maschinen.at
N O TE
N O TE
4-wire:
without
N-conductor