en
6 | BAT 131 | User information
3.6
Menu
1. Press to access the Menu.
2. Use the or to highlight the line you want to edit.
3. Press
to edit the line or save your changes.
E
4. Use or to select the function to use or edit.
5. Press
to move to the next location.
E
6. Press to return to the Menu.
Option
Description
Perform Test
Begin the Battery and System Test pro-
cedure.
Unused Battery Mo-
Perform a quick test on batteries in in-
de
ventory.
ON
Perform Unused Battery Test, Clear or
add to memory,
OFF
Turn off "Unused Battery Mode"
View Test Results
View Unused Battery Mode test results.
S/N Input
Enable or disable serial number if a bad
cell is detected.
Voltmeter
Start the test battery voltage.
View / Print
Display the previous test result. Press
the
Export / Clear Data
Export the test results (max. 100) to a
USB stick
BAT 131.
Counter
R Deletion of results.
R Shows a summary of the results of
the measurements taken.
Settings
Customize tool options to fit your needs.
Language
Select a language for the tester.
Default: English
Set Address
Create a header for your printed test re-
sults with your business location infor-
mation.
Set Time
Select 24-hour or AM/PM and set the
time.
Default: AM/PM
Set Date
Select the date format and date.
Default: MM/DD/YYYY
Contrast
Adjust the contrast setting of the tes-
ter display.
Default: 10
Temperature Units Select the temperature units Degrees °F
or Degrees °C.
Default: Degrees F
Amp Clamp
Prompt for Amp Clamp availability.
Version Info
Lists the software version, software ver-
sion date, and serial number.
Update
Update the tester's internal operating
software.
After export to an USB stick you can open the text-file with
1)
extension ""bty" preferable with Excel (se chap. 3.7).
|
1 689 989 132
2013-09-09
button to print the results.
), or delete the memory from
1)
3.7
Export data and display using Excel
i
After being stored on a USB stick, the data can be
viewed on a PC/laptop.
Procedure:
1. Switch on the BAT 131.
2. Select "EXPORT / CLEAR DATA." and press E.
3. Select "EXPORT DATA" and press E.
4. Insert the USB stick into the USB port of BAT 131
and press E.
The stored data are transferred.
5. Start Excel on a PC/laptop.
6. Insert the USB stick in the USB port of the PC/Lap-
top.
7. Select "Open file".
8. Select USB stick and open the "Mustername.bty"
file.
9. Select the "Separate" option.
10. <Continue>.
11. Select the separator "Comma".
12. <Continue>.
13. Conclude data import with <Complete>.
"
The stored data are displayed.
3.8
Special accessory
Designation
Item number
Current probe
1 681 354 034
Robert Bosch GmbH