2
Push the brake line into the clamping piece set up to the
illustrated line.
3
Hand-tighten both clamping screws.
4
To determine the correct clearance of the line, screw the
spacing screw in up to the limit stop in the
clamping piece set.
5
Tighten both clamping screws.
6
Remove the spacing screw
7
Select the flaring adapter that matches your clamping set.
8
Please grease the thread on the adapter
to prevent damages.
D I N F L A R I N G
Screw in the DIN crimping adapter up to the limit stop and
then remove it.
Completely loosen both clamping screws and remove the line
from the clamping pieces.
S A E F L A R I N G
Pay attention to the arrow attached to the flaring adapter.
Screw in the SAE flaring adapter, first in the direction of the
arrow up to the limit stop and then remove it.
Turn the adapter in opposite to the direction of the arrow into
the clamping piece up to the limit stop.
Completely loosen both clamping screws and remove the line
from the clamping pieces.