L
N
L
N
FP
WARNING: If the FIL-PILOTE interface does not use the FP wire (black), it must be
secured from access to the other wires.
DO NOT CONNECT the "FP" wire to GROUND TERMINAL.
CONNECTION OF THE DEVICE IN M/MS VERSION (WITHOUT POWER CORD)
1
3a
L
External
Fil-Pilote
N
Driver
FP
2
3b
4
5
7
8
DEVICE DISASSEMBLY
1.
Disconnect the device from electricity.
2.
Release the screw at the back of the controller casing.
3.
Take off the casing.
4.
In case of a radiator connected to a central heating system, close the valves
and remove the heating medium. For electric radiators – take it off the wall and
position it in such a way to prevent the heating medium from pouring out of the
radiator during disconnecting the heating element.
Untwist the heating element using spanner no
MAINTENANCE
1.
Disconnect the device from electricity prior to cleaning.
2.
Heating element controller should be cleaned with a dry or damp cloth with
a very small amount of detergents, which should never contain any solvents or
abrasive agents.
L
N
PE
6