GB
Insuffi cient power supply
1) After pressing ON
2) Replace battery without delay
Low voltage is shown if the red LED fl ashes 10 times after the ON button is pressed. There
is still suffi cient energy for opening approximately 50 times, but no further programming
sequences should be carried out.
When low voltage is indicated, please change the battery immediately. If the low battery sig-
nal is ignored for a long period, the number of possible opening cycles may be reduced due
to the battery's automatic discharge.
Should the battery not be accessible from the outside, in the case of a discharged or defec-
tive battery, the lock has to be opened using the override key (see 4.6 or 4.7).
4.5.1 Changing the battery – separate battery compartment
Push the sliding compartment in the direction of the arrow (grooving on sliding compartment)
and pull out. Remove the discharged battery and insert the new battery. Replace the sliding
compartment and push in until it audibly engages.
Diagram 2: Battery sliding compartment
4.5.2 Changing the battery – integrated battery compartment
Open the battery compartment lid with the Allen key (2 mm) provided and change the battery.
Diagram 3: Input unit
Page 34
82132 Code-Combi B
10 x
Kaba Mauer GmbH