GB
4.3.5 Cancellation of ordinary dual code mode
The 1
st
part of the dual code becomes the new primary code on deletion.
By pressing the key combination P and 0 all the functions previously programmed
(secondary code, dual code, time delay, opening window) are deleted.
1) Open lock with valid dual code (see 4.3.2)
2) Press ON
3) Press P
4) Enter valid dual code once more
5) Press P
6) Press 0
4.3.6 Locking
See chapter 4.1.7
4.4 Time delay (TD) and opening window (OW) functions
The time delay (TD) function refers to the period of time which must elapse before the lock
can be opened. The opening window (OW) is the period in which the lock may be opened
after the TD has elapsed. Any valid code can be provided with a TD or OW function.
4.4.1 Switching on/alteration of the TD/OW
1) Open lock with valid code
2) Press ON
3) Press P
4) Enter valid code once more
5) Press P
Press 1 when TD/OW is entered for
- primary code in parallel mode
- primary code in delegated dual code mode
6)
- dual code in ordinary dual code mode
Press 2 when TD/OW is entered for
- secondary code in parallel mode
- dual code in delegated dual code mode
Enter a 2-digit TD (01-99 minutes) and
7)
enter a single digit OW (1-9 minutes)
Example: 092 for 9 minutes TD and 2 minutes OW
8) Test newly programmed TD and OW by closing and opening once more
Page 32
82132 Code-Combi B
1 x
1 x
nd
2
part of
code deleted
1 x
Kaba Mauer GmbH