4 Lock functions
The lock should only be programmed with the lock and safe opened.
4.1 Parallel mode function
4.1.1 Opening with primary or secondary code
1) Press ON
2) Enter valid 6-digit primary or secondary code
3) Within 4 seconds turn bar handle clockwise until stop position reached
If the lock was last opened with a different code, the signal 3 x
4.1.2 Opening after 3 or more incorrect code entries
After 3 incorrect entries the lock goes into a one minute blocked status. The period in which
the lock is blocked is extended to 2, 4, 8 and a maximum of 16 minutes every time an incor-
rect code is entered. During this period the red LED fl ashes every second and it is not pos-
sible to enter any further codes. The penalty time can be overridden but not deleted with the
override key (see 4.6 or 4.7).
1) When the blocked period is over, ON may be pressed again at any time
2) Enter valid 6-digit code
Signal: invalid 6-digit code was entered during former opening attempt
3) Within 4 seconds turn bar handle clockwise until stop position reached
4.1.3 Alteration of primary code by primary code holder
1) Open lock with valid 6-digit primary code (see 4.1.1)
2) Press ON
3) Press P
4) Enter valid 6-digit primary code
5) Enter new 6-digit primary code
6) Enter new 6-digit primary code again
Test newly programmed primary code by locking and opening once
7)
more
Kaba Mauer GmbH
primary code
secondary
82132 Code-Combi B
code
appears.
penalty time
GB
1 x
1 x
3 x
/ 2 x
1 x
Page 25