4.3.3 Opening after 3 or more incorrect code entries
After 3 incorrect entries the lock goes into a one minute blocked status. The period in which
the lock is blocked is extended to 2, 4, 8 and a maximum of 16 minutes every time an incor-
rect code is entered. During this period the red LED fl ashes every second and it is not pos-
sible to enter any further codes. The penalty time can be overridden but not deleted with the
override key (see 4.6 or 4.7).
1) When the blocked period is over, ON may be pressed again at any time
2) Enter valid dual code
Signal: invalid dual code was entered during former opening attempt
3) Within 4 seconds turn bar handle clockwise until stop position reached
4.3.4 Alteration of dual code by dual code holder
1) Open lock with valid dual code (see 4.3.2)
2) Press ON
3) Press P
4) Enter valid dual code once more
5) Enter new 6-digit 1
6) Enter new 6-digit 1
7) Enter new 6-digit 2
8) Enter new 6-digit 2
9) Test newly programmed dual code by closing and opening once more
If the new partial combinations are not correctly confi rmed, the signal 3 x
Repeat the sequence.
The correct sequence of the partial combinations and its repeated confi rmation must be
adhered to.
Kaba Mauer GmbH
st
part of combination
st
part of combination again
nd
part of combination
nd
part of combination again
82132 Code-Combi B
penalty time
1 x
3 x
1 x
1 x
appears.
GB
/ 2 x
/ 2 x
Page 31