2 - TECHNICAL DATA
Lenght (mm)
Widht (mm)
Height (mm)
Weight (Kg)
Max. force (tons.)
Log capacity (mm)
Diameter of the log to be split (cm)
Hydraulic oil tank capacity (lt.)
Hydraulic oil total capacity (lt.)
Supply
Absorption
Power
Noise ≤ 81 dB(A) measured at the height of the operator's ear in the working position with the log splitter in operation
The ears must be suitably protected (ear defenders).
2.1 - Right way to lift the machine
The machine must be lifted by means of a fork lift truck, placing the forks as shown in fig.18a, page 4, or by a sling equipped with a special lift-band with
capacity bigger than 300 Kg., as shown in fig.18b, page 4.
2.2 - Size of the logs to be split
Figure 2 on page 2 shows the maximum log sizes that can be split.
The diameter of the log is indicative: a small log can be difficult to split if it has knots or is of a particularly twisted fibre.
2.3 - Recommended oils
We recommend use of the following oils for the hydraulic cylinder:
SHELL TELLUS T22
ARAL VITAM GF22
SP ENERGOL HCP22
MOBIL DTE11 or equivalent
DO NOT USE OTHER GRADE OILS.
D22030800 - v.1 - UPD 291209
SPV5 E TF
~ 600
~ 500
~ 1030÷1500
~ 65
~ 5
~ 540
~ 10÷30
~ 2,2
~ 3,5
230V 50Hz Single-phase 230V 50Hz Single-phase
~ 11A
2,5 Hp - 1,85 KW
SPV5 E TM
~ 600
~ 500
~ 1030÷1500
~ 70
~ 5
~ 560 / 1040
~ 10÷30
~ 2,2
~ 3,5
~ 11A
2,5 Hp - 1,85 KW