5.3
INSTALLING NON-COMBUSTIBLE BOARD
NON-COMBUSTIBLE FINISHING MATERIAL
COMBUSTIBLE
MATERIAL
A
NOTE: For detailed installation instructions on the 4-sided frame, optional faceplate or bevelled trims
refer to the installation instructions provided with the kit.
A joint compound that is resistant to heat and cracking should be used when taping and mudding
seams.
NON- COMBUSTIBLE MATERIAL
FINISHING DIMENSIONS
Ref
HD35
33"
A
(838mm)
33 3/4"
B
(857mm)
Non-combustible Material Defi nitions
Material which will not ignite and burn. Materials consisting entirely of steel, iron, brick, tile, concrete, slate,
glass or plasters, or any combination thereof are suitable.
Materials that are reported as passing ASTM E 136, Standard Test Method for Behaviour of Materials in a
Vertical Tube Furnace at 750°C and UL763 shall be considered non-combustible materials.
All manuals and user guides at all-guides.com
NON-COMBUSTIBLE
MATERIAL SUCH AS TILE,
MARBLE GRANITE, ETC.
7 3/8"
187mm
MIN
B
1 1/4"
32mm
MIN
HD40
HD46
38"
44"
(965mm)
(1117mm)
33 3/4"
33 3/4"
(857mm)
(857mm)
COMBUSTIBLE FINISHING MATERIAL
COMBUSTIBLE
MATERIAL
E,
B
A
COMBUSTIBLE MATERIAL
FINISHING DIMENSIONS
Ref
HD35
35 3/4"
A
(908mm)
35 1/2"
B
(902mm)
41"
C
(1041mm)
NOTE: THREE BRACES
ARE REQUIRED.
NON-COMBUSTIBLE
(SUPPLIED)
6 1/2"
[165mm
MIN
C
HD40
HD46
40 3/4"
46 3/4"
(1035mm)
(1187mm)
40 1/4"
46 1/4"
(1022mm)
(1175mm)
41"
41"
(1041mm)
(1041mm)