S
Insulation thickness
dn
air space around appliance
minimum distance between rear and
dR
combustible material
minimum distance between sides and
dS
combustible material
minimum distance between the top and
dC
combustible material in the ceiling
minimum distance between front and
dp
combustible material
minimum distance between the front and
dF
combustible material in the front radiation
zone on the floor
minimum distance between the front and
dL
combustible material in the front radiation
zone on the side
minimum distance between bottom and
dB
combustible material
40
PU53v3-58v3
PU67v3-77v3
with non-
with non-
without insulation
flammable
flammable
:
insulation :
insulation :
50 mm
-
50 mm
5 mm
50 mm
5 mm
55 mm
150 mm
55 mm
55 mm
150 mm
55 mm
550 mm
500 mm
550 mm
1000 mm
1000 mm
1700 mm
600 mm
600 mm
1000 mm
500 mm
500 mm
700 mm
400 mm
400 mm
400 mm
Instructions for use
Ignition
1. Remove the excess ash, place 2 logs weighing +/- 1 kg in the centre of the fire bed,
place some kindling on top and place a solid firelighter on the pile thus formed.
2. Then light the firelighter.
3. To start the appliance correctly, we recommend that you slightly ajar the door
door slightly ajar, open the outside air supply to the maximum for 10 to 15 minutes, the time
to reach a sufficient temperature in the firebox.
without insulation
4. When the glass is hot, be sure to close the door. You can now
:
the control lever to regulate the air supply to the right, depending on the heat
the desired heat.
-
Do not exceed the maximum load allowed per hour (see page 8).
- To ensure correct operation, do not completely remove the ashes from the fireplace.
- The fireplace is designed for use with the door closed, after the fire has started.
50 mm
- Reload when only glowing embers remain.
- We recommend the use of solid ignition blocks.
Do not use liquid flammable products! Never use petrol, lamp fluid, kerosene
150 mm
paraffin, barbecue lighter fluid, alcohol or similar liquids to ignite or rekindle' combustion in the
appliance. Keep all such liquids well away from the appliance during use
150 mm
Combustion
500 mm
Combustion air
1700 mm
This airtight appliance is fitted with an external air intake for the combustion air.
(diameter 100mm).
The combustion air intake is adjusted using the control lever
1000 mm
located in the centre of the appliance: use your cold hand or a glove.
Positioned to the left, it opens the combustion air intake completely.
700 mm
Turn it to the right to close the combustion air supply almost completely.
400 mm
The combustion chamber door must always be closed during operation and must only be
opened to add fuel, light or remove ash.
Close the combustion air control when not in use, after the combustion process has been
combustion process is complete.
WARNING - Fumes escaping from blocked flues are dangerous.
dangerous. Keep the flue and connection pipe clear;
Clean in accordance with the instructions. Use
only recommended fuels. Read the operating instructions.