Use the USB port as shown.
9.14
Defrosting the cooling device
Humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling capacity.
NOTICE! Damage hazard
Never use hard or pointed tools to remove ice or to loosen objects which have frozen in place.
To defrost the cooling device proceed as follows:
1. Remove the contents of the cooling device.
2. If necessary, place the contents in another cooling device to keep them cold.
3. Switch off the cooling device.
4. Leave the lid open.
5. Wipe off defrosted water.
9.15
Replacing the AC fuse
DANGER! Electrocution hazard
Disconnect the power supply and the connection cable before you replace the device fuse.
1. Disconnect the power supply to the device.
2. Remove the connection cable.
3. Pry out the fuse insert (
4. Replace the defective glass fuse with a new one of the same type and rating (Fast acting, 4 A, 250 V).
5. Press the fuse insert back into the housing.
6. Reconnect the power supply to the device.
Fig. 
on page 10 2) with a screwdriver.