Ingeteam
2.8. Specifications tables
DC inputs
Recommended power range of PV array
Maximum input voltage
(2)
MPP Voltage range
Operating voltage range
Minimum voltage for Pnom
Maximum short circuit current
Maximum inverter backfeed current to the
PV array.
MPPT
Number of strings versions P and P+
Number of strings versions S and S+
Maximum input current
Maximum input current per string
AC output
Rated power
Maximum continuous power
Max. temperature for nominal power
Maximum current
Maximum transient current
Maximum output fault current
Maximum output overcurrent protection
Rated voltage
Voltage range
Nominal frequency
Cosine of Phi
Adjustable cosine of phi
THD
Performance
Maximum efficiency
Euroefficiency
General data
Cooling system
Air flow
Weight
Measurements (height x width x depth)
Standby current
(4)
Night consumption
Operating temperature
Relative humidity (without condensation)
Maximum altitude of the installation
Protection class
Markings
EMC and safety regulations
Grid connection regulations
Depending on the type of installation and the geographic location.
(1)
temperatures.
For each ºC of increase, the output power is reduced by 1.8 %.
(3)
to 16 A.
88
10TL
10.6 ~ 13.5 kWp
15.5 ~ 19.8 kWp
(1)
1000 V
560 ~ 820 V
560 ~ 1000 V
560 V
40.7 A
31.9 Arms
1
5
1
37 A
11 A
10 kW
10 kW
55 ºC
(3)
29 A
29 A
< 31.9 Arms
(60 ms)
31.9 Arms
400 V
187 ~ 528 V
50 / 60 Hz
1
Yes. Smax
= 10 kVA;
Qmax = 10 kVAR
Qmax = 15 kVAR
< 3 %
98.5 %
98.3 %
200 m
/h
3
46.8 Kg
< 10 W
1 W
–25 ~ +65 ºC
0 ~ 95 %
4000 m
IP65
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12, EN
62109-1, EN 62109-2, IEC62103, EN 50178, FCC Part 15, AS3100
RD1699/2011, DIN V VDE V 0126-1-1, EN 50438, CEI 0-21, VDE-AR-N 4105:2011-08, G59/2,
G83/2
, P.O.12.3, AS4777.2, AS4777.3, IEC 62116, IEC 61727, UNE 206007-1, ABNT NBR 16149,
(5)
ABNT NBR 16150, South African Grid code, Chilean Grid Code, Romanian Grid Code, Ecuadorian
Grid Code, Peruvian Grid code, IEEE 929, Thailand MEA & PEA requirements
Never exceed this value. Consider the voltage increase of the panels 'Voc' at low
(2)
15TL
20TL
20.5 ~ 26.1 kWp
1000 V
1000 V
560 ~ 820 V
560 ~ 820 V
560 ~ 1000 V
560 ~ 1000 V
560 V
560 V
40.7 A
40.7 A
31.9 Arms
31.9 Arms
1
1
5
5
1
1
37 A
37 A
11 A
11 A
15 kW
20 kW
15 kW
20 kW
55 ºC
55 ºC
29 A
29 A
29 A
29 A
< 31.9 Arms
< 31.9 Arms
(60 ms)
(60 ms)
31.9 Arms
31.9 Arms
400 V
400 V
187 ~ 528 V
187 ~ 528 V
50 / 60 Hz
50 / 60 Hz
1
1
Yes. Smax
Yes. Smax
= 15 kVA;
= 20 kVA;
Qmax = 20 kVAR
< 3 %
< 3 %
98.5 %
98.5 %
98.4 %
98.3 %
Forced ventilation
200 m
/h
200 m
/h
3
3
46.8 Kg
46.8 Kg
730 x 700 x 250 mm
< 10 W
< 10 W
1 W
1 W
–25 ~ +65 ºC
–25 ~ +65 ºC
0 ~ 95 %
0 ~ 95 %
4000 m
4000 m
IP65
IP65
CE
Consumption from the PV array.
(4)
ABO2011IQM01_A - Installation and Operation Manual
Unit description
28TL
33TL
28.7 ~ 36.4 kWp
33.9 ~ 42.9 kWp
1000 V
1000 V
560 ~ 820 V
560 ~ 820 V
560 ~ 1000 V
560 ~ 1000 V
560 V
560 V
57.2 A
67.1 A
45.1 Arms
52.8 Arms
1
1
8
8
1
1
52 A
61 A
11 A
11 A
28 kW
33 kW
28 kW
33 kW
45 ºC
45 ºC
41 A
48 A
41 A
48 A
< 45.1 Arms
< 52.8 Arms
(60 ms)
(60 ms)
45.1 Arms
52.8 Arms
400 V
400 V
304 ~ 528 V
304 ~ 528 V
50 / 60 Hz
50 / 60 Hz
1
1
Yes. Smax
Yes. Smax
= 28 kVA;
= 33 kVA;
Qmax = 20 kVAR
Qmax = 20 kVAR
< 3 %
< 3 %
98.3 %
98.3 %
97.9 %
97.9 %
400 m
/h
400 m
/h
3
3
51.5 Kg
51.5 Kg
< 10 W
< 10 W
1 W
1 W
–25 ~ +65 ºC
–25 ~ +65 ºC
0 ~ 95 %
0 ~ 95 %
4000 m
4000 m
IP65
IP65
Only for inverters with outputs up
(5)