1.
Prepare the cable for connection:
USE THE RIGHT CABLE
Indoor Power Cable (if applicable): H05W-F or H05V2V2-F
Outdoor Power Cable: H07RN-F
Signal Cable: H07RN-F
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable, signal cable, fuse, and switch needed is determined by the maximum
current of the unit. The maximum current is indicated on the nameplate located on the side panel of
the unit. Refer to this nameplate to choose the right cable, fuse, or switch.
a.
Using wire strippers, strip the rubber jacket from bath ends of cable to reveal about 40mm
(1.57in) of the wires inside.
b.
Strip the insulation from the ends of the wires.
c.
Using a wire crimper, crimp u-lugs on the ends of the wires.
PAY ATTENTION TO LIVE WIRE
While crimping wires, make sure you dearly distinguish the Live ("L") Wire from other wires.
WARNING
All wiring work must be performed strictly in accordance with the wiring diagram located inside
of wire cover of the outdoor unit.
2.
Unscrew the electrical wiring cover and remove it.
3.
Unscrew the cable damp below the terminal black and place it to the side.
4.
Connect the wire according to the wiring diagram, and firmly screw the u-lug of each wire to its
corresponding terminal.
5.
After checking to make sure every connection is secure, loop the wires around to prevent rain
water from flowing into the terminal.
6.
Using the cable damp, tasten the cable to the unit. Screw the cable damp down tightly.
7.
lnsulate unused wires with PVC electrical tape. Arrange them so that they do not touch any
electrical or metal parts.
8.
Replace the wire cover on the side of the unit, and screw it in place.
NOTE: lf the cable damp looks like the following, please select the appropriate through-hole according to
the diameter of the wire.
Cover
Screw
4