9.
Then wrap up the connectors with the black insulation material, for the top exposed part, use the
white insulation material (supplied in Accessories box) to wrap it up completely as shown in Fig.4.13.
Fig. 4.13
10.
At last, use the tape to wrap the refrigerant pipe and connecting cable together.
G
NOTE ON PIPING ANGLE
Refrigerant piping can exit the indoor unit from Left-rear side(when you're facing the back of the
unit)
Fig. 4.14
CAUTION
Be extremely careful not to dent or damage the piping while bending them away from the unit.
Any dents in the piping will affect the unit's performance.
Step 5: Prepare refrigerant piping
By default, the drain hose is attached to the left hand side of unit (when you're facing the back of the unit).
However, it can also be attached to the right-hand side. To ensure proper drainage, attach the drain hose
on the same side that your refrigerant piping exits the unit.
4