Note about Fluorinated Gasses(Not applicable to the unit
using R290 Refrigerant)
1. This air-conditioning unit contains fluorinated
greenhouse gasses. For specific information on the type
of gas and the amount, please refer to the relevant label
on the unit itself or the "Owner's Manual - Product
Fiche" in the packaging of the outdoor unit. (European
Union products only).
2. lnstallation, service, maintenance and repair of this unit
must be performed by a certified technician.
3. Product uninstallation and recycling must be performed
by a certified technician.
4. For equipment that contains fluorinated greenhouse
gases in quantities of 5 tonnes of CO2 equivalent
or more, but of less than 50 tonnes of CO2 equivalent, lf
the system has a leak detection system installed, it must
be checked for leaks at least every 24 months.
5. When the unit is checked for leaks, proper
record-keeping of all checks is strongly recommended.
WARNING for Using R32/R290 Refrigerant
• When flammable refrigerant are employed, appliance
shall be stored in a well -ventilated area where the room
size corresponds to the room area as specifiec for opera-
tion.
For R32 frigerant models:
Appliance shall be installed, operated and stored in a
room with a floor area larger than 4m2 . For R290 refrig-
erant models, appliance shall be installed, operated and
stored in a room with a floor area larger than:
<=9000Btu/h units: 13m2
> 9000Btu/h and <=12000Btu/h units: 17m2
> 12000Btu/h and <=18000Btu/h units: 26m2
> 18000Btu/h and <=24000Btu/h units: 35m2
4