1) Select the channel you wish to associate with the
SL3163 control unit on the remote control
2) Quickly press the down wall button 15 times; alter-
natively, press the button on the SL3163 control unit
15 times or until the blind moves 3 seconds in one di-
rection and another 3 seconds in the opposite direc-
tion (in case of pleated/roller blinds, this movement
may be barely perceptible)
4) Press the
and
at the same time. When the LED on the control unit
starts flashing, the procedure is completed.
Note: If the control unit is mistakenly connected with
reversed electrical connections towards the blind
and also towards the wall push button panel, the
procedure carried out via the wall button will identify
this error and the SL3163 control unit will adapt its
operation without the need to correct the electrical
connection. This function is not active when the
SL3163 control unit is programmed via its own but-
ton; consequently, should you notice that the blind
responds to the radio commands in the opposite way,
it will be necessary to reverse the electrical connec-
tions to the blind.
If you want to create a group of SL3163 control units
that are associated with the same channel, you can
perform step 2 on different SL3163 control units and,
within 10 seconds, perform step 3 only once.
Reset of stored radio channels
This procedure will cancel the storage of any radio
channel on the SL3163 control unit, including that
of other remote controls, and any associations with
Wise HUB.
1) Keep the button on the SL3163 control unit pressed
for at least 15 seconds until the second
change in flashing speed begins (very fast flashing)
buttons on the remote control