as well as manage the complete installation database using the
EEdbase software.

5) MANUAL PROGRAMMING

In the case of standard installations where no advanced functions
are required, it is possible to proceed to manual storage of the
transmitters, making reference to programming table A and to the
example for basic programming in Fig.2.
1) If you wish the transmitter to activate output 1, press pushbutton
SW1, otherwise if you wish the transmitter to activate output
2, press pushbutton SW2.
2) If you wish to obtain functions other than monostable activation,
refer to table A – output activation.
3) When LED DL1 starts blinking, press hidden key P1 on the
transmitter, LED DL1 will remain continuously lit.
Note: Hidden key P1 appears differently depending on the
transmitter model.
4) Press the key of the transmitter to be memorized, LED DL1
will flash quickly to indicate that it has been memorized suc-
cessfully. Flashing as normal will then be resumed.
5) To memorize another transmitter, repeat steps 3) and 4).
6) To exit memorizing mode, wait for the LED to go off comple-
tely or press the key of a remote control that has just been
memorized.
IMPORTANT NOTE: ATTACH THE ADHESIVE KEY LABEL TO
THE FIRST MEMORISED TRANSMITTER (MASTER).
In the case of manual programming, the first transmitter assigns
the key code to the receiver; this code is necessary in order to
carry out subsequent cloning of the radio transmitters.
5.1) Transmitter storage via radio in self-learning mode
(DIP1 ON)
This mode is used to copy the keys of a transmitter already stored
in the receiver memory, without accessing the receiver.
The first transmitter is to be memorised in manual mode (see
paragraph 5).
a) Press hidden key P1(fig.4) on the transmitter already memo-
rised.
b) Press key T on the transmitter already memorised, which is
also to be attributed to the new transmitter.
c) Within 10 sec., press key P1 on the new transmitter to be
memorised.
d) Press key T to be attributed to the new transmitter.
e) To memorise another transmitter, repeat the procedure from
step (c) within a maximum time of 10 seconds, otherwise the
receiver exits the programming mode.
f)
To copy another key, repeat from step (a), having waited for the
receiver to exit the programming mode (or after disconnecting
the receiver from the power supply).
Note: with DIP1 ON/OFF, storage can also be carried out in
manual mode.
WARNING: Maximum protection from storage of foreign
codes is obtained by having the DIP1 OFF and programming
in MANUAL mode or by means of the Universal palmtop
programmer (Fig. 3).
6) RADIO-TRANSMITTER CLONING
Rolling-code cloning (DIP2 OFF)/ Fixed-code cloning (DIP2
ON).
Make reference to the Universal palmtop programmer Instructions
and the CLONIX Programming Guide.
7) ADVANCED PROGRAMMING: COLLECTIVE RECEIVERS
Make reference to the Universal palmtop programmer Instructions
and the CLONIX Programming Guide.
INSTALLATION MANUAL
8) MAINTENANCE
The maintenance of the system should only be carried out by
qualified personnel regularly. MITTO transmitters are powered
by a single 12V lithium battery (23A type).
Any reduction in the transmitter capacity may be due to the batteries
getting flat. When the led of the transmitter flashes, it means that
the batteries are flat and must be replaced.
9) DISPOSAL
ATTENTION: disposal should only be carried out by qualified
personnel.
Materials must be disposed of in conformity with the current
regulations.
In case of disposal, the system components do not entail any
particular risks or danger. In case of recovered materials, these
should be sorted out by type (electrical components, copper,
aluminium, plastic etc.).
For battery disposal, refer to the current regulations.
The descriptions and illustrations contained in the present
manual are not binding. The Company reserves the right to
make any alterations deemed appropriate for the technical,
manufacturing and commercial improvement of the product,
while leaving its essential features unchanged, at any time and
without undertaking to update the present publication.
ENGLISH
CLONIX/MITTO - Ver. 06 - 9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Clonix 2Mitto 2Mitto 4

Table des Matières