Changing the torque level
Example: When changing the torque level from 23
to 34
Fig.8
1.
Press the setting button several times until the
indicator shows 2-digit number which stands for
the current setting of the torque level.
2.
Press and hold the setting button until the number
in the tens place starts blinking.
3.
Set the number in the tens place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "4" in a cycle.
4.
Press and hold the setting button until the number
in the ones place starts blinking.
5.
Set the number in the ones place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" in a cycle.
6.
Press and hold the setting button for a few
seconds.
NOTE: If you are not sure which torque level is suit-
able for your work, set "FF" so that the tool operates
in the Free mode.
NOTE: If you input "00", "FF" is displayed instead of
"00".
Changing the rundown level
Example: When changing the rundown level from
L1 to L2
Fig.9
1.
Press the setting button several times until the
indicator shows 2 characters beginning with "L"
followed by a number. This stands for the current
setting of the rundown level.
2.
Press and hold the setting button until the indica-
tor starts blinking.
3.
Set the rundown level. Every time you press the
setting button, the indicator shows from "L1"
to "L7" in a cycle. The highest sensitivity of the
fastener seating is "L1" and "L7" is the lowest
sensitivity.
4.
Press and hold the setting button for a few
seconds.
Changing the shortest workable time
range
Example: When changing the shortest workable
time range from 2.5 to 3.6
Fig.10
1.
Press the setting button several times until the
indicator shows "Lo" and number alternatively.
This stands for the current setting of the shortest
workable time range.
2.
Press and hold the setting button until the number
in the ones place starts blinking.
3.
Set the number in the ones place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" in a cycle.
4.
Press and hold the setting button until the number
in the decimal place starts blinking.
5.
Set the number in the decimal place by pressing
the setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" in a cycle.
6.
Press and hold the setting button for a few
seconds.
NOTE: When you set the value smaller than "0.1" for
the shortest workable time range, the indicator shows
"-.-" and the shortest workable time range becomes
disabled. To input "-.-", set the value to "0.9", and
then press the setting button when the number in the
decimal place is blinking.
9 ENGLISH