Changing the longest workable time
range
Example: When changing the longest workable time
range from 2.5 to 3.6
Fig.11
1.
Press the setting button several times until the
indicator shows "HI" and number alternatively.
This stands for the current setting of the longest
workable time range.
Measuring an actual operation (Self-diagnosis)
NOTICE:
This function is available by default. If you have disabled the Field Setting mode on the computer,
enable the Field Setting mode beforehand. Refer to the instruction manual of "Makita Industry Tool Settings" for
how to configure.
You can measure the torque level and operating time of an actual operation by operating the tool. Measured torque
level and time can be used for such as;
Reproducing a torque control technic of a well-skilled worker.
A time reference for the setting of the shortest/longest workable time range.
Measuring the torque level and operating time
1.
Press the setting button several times until "Ad." is displayed on the indicator.
2.
Press and hold the setting button until the indicator shows "Ch."
3.
Perform the operation that you want to measure the operating time.
If you have configured the torque level, operate the tool until it stops in the Tightening Auto Stop mode.
If you have not configured the torque level (Free mode), operate the tool as necessary.
4.
Check the measured result. Press the setting button once to display the actual torque level, and press it one
more time to display the actual operating time.
Every time you press the setting button, the indicator shows "Ch.", the number of actual torque level, and the
number of actual operating time in a cycle.
5.
Press and hold the setting button to exit the Self-diagnosis.
NOTE: The Tightening Auto Stop mode works even in the Self-diagnosis. If you want to measure the torque level
without limitation, set the torque level "FF" (Free mode) and perform the procedures above.
NOTE: If "- -" is displayed on the indicator, the impact did not work or the torque level is higher than 40. If "-.-" is
displayed in the indicator, the operating time exceeded 9.9 seconds.
In case the impact did not work: Remeasure the torque level with longer workable time.
In case the torque level is higher than 40: The tool cannot measure the torque level. Use the tool with higher
torque range if available.
In case the operating time exceeded 9.9 seconds, the workable time range is not available.
2.
Press and hold the setting button until the number
in the ones place starts blinking.
3.
Set the number in the ones place by pressing the
setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" in a cycle.
4.
Press and hold the setting button until the number
in the decimal place starts blinking.
5.
Set the number in the decimal place by pressing
the setting button briefly. Every time you press the
setting button, the indicator shows the number
from "0" to "9" in a cycle.
6.
Press and hold the setting button for a few
seconds.
NOTE: When you set the value larger than "9.9" for
the longest workable time range, the indicator shows
"-.-" and the longest workable time range becomes
disabled. To input "-.-", set the value to "9.9", and
then press the setting button when the number in the
decimal place is blinking.