Failure code
E0
E1
E2
E7
C1
E3
E4
EL
EH
EU
106
VH334T2 4 JUn.indd 106
VH334T2 4 JUn.indd 106
Problem
No Auto-Recovery
Zero erros.
Ceramic
plate
temperature
sensor failure--open circuit.
Ceramic
plate
temperature
sensor failure--short circuit.
Ceramic
plate
temperature
sensor failure.
High temperature of ceramic
plate sensor.
Temperature sensor of the NTC
failure--open circuit.
Temperature sensor of the NTC
failure--short circuit.
Supply voltage is below the
rated voltage.
Supply voltage is above the
rated voltage.
Communication error.
FR
NL
Solution
Reinsert the connection between the
display board and the power board.
Replace the power board.
Check the connection or replace the
ceramic plate temperature sensor.
Wait for the temperature of ceramic
plate return to normal.
Touch "ON/OFF" button
unit.
Replace the display board.
Please inspect whether power supply
is normal.
Power on after the power supply is
normal.
Reinsert the connection between the
display board and the power board.
Replace the power board or the
display board.
EN
PT
to restart
5/6/2024 9:25 AM