KJ 60
TOPPING UP THE OIL-DYNAMIC CIRCUIT
You need to top up the oil-dynamic circuit after a long period of work, when you note a power loss. Put the riveting tool (DWELL
AND NOT FED) in a horizontal position and remove the plug (A), by means of a 5 mm Allen wrench (equipped with the riveting
tool); during this operation, check the oil level in order to avoid any overflowing. Then, slowly pour the oil HLP 32 cSt into the
bellows container (X) which shall be screwed to its seat on the plug (A). While keeping the riveting tool in a horizontal position and
starting air feeding, push the tensile strength button and make the riveting tool carry out some cycles until air bubbles inside the
container (X) stop coming out. This condition indicates that the topping up of the oil has fully been achieved. At this point stop the
air feeding and, while keeping the riveting tool in a horizontal position, unscrew and close up the container (X) and the plug (A).
WARNING: it is very important to follow the about mentioned instructions and use gloves. If you need to empty fully the hydraulic
circuit, you must put the oil in a suitable container and contact a Company that is authorized to discharge any waste
WARNING! Before disconnecting the compressed air hose, make sure that it is not under pressure!
5 mm.
A
WARNING: Make sure that the oil filler cap
GB
(A) is tightened at a torque corresponding
to Min. 5 Nm ÷ Max. 8 Nm.
DISPOSAL OF THE RIVETING TOOL
Follow the prescriptions of the national laws for disposing of the riveting tool.
After disconnecting the tool from the pneumatic system, disassemble and split all the components according
to the material: steel, aluminium, plastic material, etc.
Then proceed to scrap the materials in accordance with current laws.
Revisione - 21
GB
We recommend to use oil HLP 32 cSt or similars.
min. 5 Nm
max. 8 Nm
Date 07-2016
X
13