Low Oil Shutdown
If the engine oil drops below a preset level, an oil switch will stop the engine. Check oil level with
dipstick.
If oil level is between the LOW and HIGH mark on dipstick:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is corrected.
If oil level is below the LOW mark on dipstick:
1.Add oil to bring level to HIGH mark.
2.Restart engine and if the engine stops again a low oil condition may still exist. DO NOT try to restart
the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is corrected.
Do Not Overload Generator
Overloading a generator in excess of its rated wattage capacity can result in damage to the
generator and to connected electrical devices. To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to stabilize.
3. Plug in and turn on the first item. It is best to attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Overload Operation
The overload indicator light will blink when the load exceeds 3550W(approximately)
to the receptacles in 30 seconds. If the load exceeds 3680W(approximately), the light will turn on and
cut power to the receptacles in 2 seconds.
How to Correct
1. Disconnect any electrical devices, and then stop the engine.
2. Reduce the total wattage of connected electrical devices until it is within the generator's rated output.
3. Inspect the Air Inlet and Control Panel for any blockage. Remove blockage if found.
4. Restart Engine.
Parallel Operation
Any two FIRMAN inverter generators with parallel ports, including two FIRMAN inverters model WH03242
can be paralleled to increase the total available electrical power to 6000 Watts. A FIRMAN Parallel
kit (not included) is required for parallel operation. For Kit availability, call customer Service at 1-844-
347-6261 or visit: www.firmanpowerequipment.com.