Cembre B1350-UC Notice D'utilisation Et Entretien page 10

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

NOTE:
To display the momentary force or pressure during
the work cycle, select the appropriate display from the
menu (Ref. to § 7). When the operating button is released
before the motor stops automatically, the display will show
the peak force (Fp) or the peak pressure (Pp) reached at
that instant.
To complete the work, press the operating button again until the motor stops automatically; the dis-
play will show the maximum force or pressure reached followed by "OK" to confirm correct operation.
The display "ERROR", combined with a beep and the LEDs flashing, indi-
cates an incorrect crimping procedure caused by the work cycle being
interrupted before the control parameters (force/pressure) of the tool
are reached.
This error appears when the pressure release button has been operated and the tool has already
reached a pressure > 100 bar. In this case, repeat the compression by pressing and holding the
operating button until the motor stops automatically.
2.4) Release of dies
By operating the pressure release button (5), the ram will retract
and open the dies.
2.5) LED Worklights
Whilst the tool is in operation, the compression area is illuminated
by two high luminosity LED Worklights that switch off automatical-
ly at the end of the cycle.
The LED Worklights can be disabled by following the procedure described in § 7.2.
2.6) Head rotation
For ease of operation, the tool head can rotate through 180°, allowing the operator to work in the
most comfortable position.
Do not attempt to rotate the head when the hydraulic circuit is pressurised.
2.7) Capacitive touch button for menu selection
This button is located under the display and allows selection of various
screens (Ref. to § 7); it only works when the display is on.
Wearing gloves or using other objects may inhibit the operation of the
button, therefore use a bare finger to apply only a light touch.
Do not apply pressure to or stab at the touch button, a light touch using a bare finger is
sufficient. The command pulse is sent when the finger releases the button.
F
= 125.2 kN
m
F
= 102.3 kN
p
P
= 692 bar
m
P
= 565 bar
p
5
F
= 125.2 kN
m
OK
P
= 692 bar
m
OK
ERROR
 
 
 
3 SEC.
10