DRAIN CONNECTION HEIGHT
The drain connection method depends on the height of the drain hose
connection.
IMPORTANT: Failure to connect the drain hose at a height of 18" with air
gap (not provided) OR to create a drain loop with a minimum height of
32" (81.3 cm) will result in improper draining of the dishwasher.
WATER SUPPLY REQUIREMENTS
Water pressure from the hot water supply line must be between
•
20-120 psi (138-862 kPa).
Water heater that is adjusted to a water temperature of 120°F to 150°F
•
(49°C to 65.5°C).
A 90° elbow is required to be attached to the water valve, prior to the
•
connection of the water line.
3/8
A
" min. diameter copper tubing water line extending at least 24"
•
(61 cm) from the rear wall, and routed to connect to the front left-hand
side of the dishwasher.
A hand shut-off valve in an accessible location, such as under the sink
•
(optional, but strongly recommended).
ELECTRICAL REQUIREMENTS
WARNING
10
IMPORTANT:
The dishwasher must be supplied with 120 volt, 60 Hz., and connected
•
to a dedicated, properly grounded branch circuit, protected by a 15 or
20 ampere circuit breaker or time delay fuse.
Maximum of two field wiring supply conductors (12 AWG Maximum)
•
plus one grounding conductor are permitted in the terminal box.
Use Only copper wire.
•
Wiring must be 2-wire with ground.
•
Use a UL Listed/CSA Approved metallic strain relief.
•
Be sure that the electrical connection and wire size are adequate and
•
in conformance with the National Electrical Code, ANSI/NFPA No.
70-latest edition and all local codes and ordinances.
If the electrical supply does not meet the above requirements, call a
•
licensed, qualified electrician before proceeding.
Electrical Shock Hazard
Installation and service must be performed by a
•
qualified installer or service agency.
Always disconnect the power before servicing this unit.
•
This appliance must be properly grounded.
•
Failure to do so could result in death, fire, or electrical
•
shock.