(9) DC Current
Range
OL Reading
60.00A
66.00A
600.0A
660.0A
The measured value <5.0A, add 10 dgt to the accuracy.
Overload Protection : AC/DC 600A
(10) AC Current
Range
OL Reading
60.00A
66.00A
600.0A
660.0A
Add 10 dgt to the accuracy when <5.0A.
Add 1% to the accuracy when >100Hz.
Frequency Response : (Sine Wave) 45 ~ 400Hz
Overload Protection : AC/DC 600A
(11) Flexible Current Probe
Range
OL Reading
300.0A
330.0A
3000A
3300A
Frequency Response : 45Hz to 400Hz
Accuracy does not include accuracy of the Flexible Current Probe.
Overload Protection : AC/DC 1000V
(12) Frequency
Range
OL Reading
100.00Hz
100.00Hz
1000.0Hz
1000.0Hz
10.000kHz
10.000kHz
Minimum Sensitivity :
> 5V (for ACV 1Hz ~ 10kHz)
> 8A (for ACA 1Hz ~ 1kHz)
Minimum Frequency : 1Hz
Overload Protection : AC/DC 1000V and 600A
Resolution
Accuracy
0.01A
±(2.0% + 5D)
0.1A
Resolution
Accuracy
0.01A
±(2.0% + 5D)
0.1A
Resolution
Accuracy
0.1A
±(1.5% + 5D)
1A
Resolution
Accuracy
0.01Hz
±(0.3% + 3D)
0.1Hz
0.001kHz