LINEARIZATION PARAMETERS
Only if linearization to specification was configured (Con2 = x2 xx), press key M >5
seconds at parameter level for changing over to linearization parameter
display/operation (new level). If linearization to specification was not configured, press
key M > 5 seconds for changing over to the configuration level.
+ The parameter level is left after a timeout of 30 s or when pressing key M
shortly after the last parameter.
Linearization parameters:
Linearization parameter name
Number of segments
Input value f. 1st linearization segment point
Output value f. 1st linearization segment point
Input value f. 2nd-9th linearization segment point
Output value f. 2nd-9th linearization segment point
Ü Display in units of the displayed physical quantity, the decimal point is determined by "dP".
* Display in units of the physical quantity of the input variable, potentiometric transducer in %.
Press key M during more than 5 seconds for switch-over to configuration level.
9499-040-47801
Symbol
Adjustment range
n
1...8
InI
-999...In2 *
OuI
-999...9999 Ü
Inx
In(n-1)...In(n+1) *
Oux
-999...9999 Ü