Requirements for connecting the torch
1 Use only compressed air which is free of dirt, oil and water.
2 Ensure that the connections are properly assigned and tightened.
3 Ensure that the correct air pressure (flow pressure) and correct air volume
are set. Insufficient air volumes can lead to torch overheating.