Waste water tank cap
1
Support
2
Level
3
5. Charge the batteries if necessary.
Gray intelligent key
The gray Intelligent Key grants the supervisory staff ex-
tended authorizations and setting options.
1. Insert the Intelligent Key.
2. Select the desired function by turning the info button.
Transport trip
1. Set the program switch to "TRANSPORT MODE".
2. Press the info button.
The following functions can be performed in the TRANS-
PORT MODE menu:
● Set maximum speed
● Display operating hours counter
● Delete maintenance counter
● Show software versions
● Set R or D cleaning head
● Switch speed-dependent water dosing on/off
● Set after-running times
● Set language
● Key management
● Switch attachment kits on/off
● Activate factory setting
Maximum speed
In the menu "max speed" the maximum speed can be lim-
ited.
1. Turn the info button until "max speed" is shown in the
display.
2. Press the info button.
3. Turn the info button until the desired maximum speed is
displayed.
4. Press the info button.
Note
The working speed cannot exceed the set maximum
speed.
Resetting the maintenance counter
If a maintenance task shown in the display has been car-
ried out, the corresponding maintenance counter must
then be reset.
1. Turn the info button until "maintenance count." is dis-
played.
2. Press the info button.
The meter readings are displayed.
18
3. Rotate the info button until the counter to be deleted is
highlighted.
4. Press the info button.
5. Select "yes" by rotating the info button.
6. Press the info button.
The counter is deleted.
Adjusting the cleaning head
1. Turn the info button until "brush head" is displayed in the
menu.
2. Press the info button.
3. Turn the info button until the type of cleaning head in-
stalled is highlighted.
"Roll" = R cleaning head
"Disc" = D cleaning head
4. Press the info button.
Speed-dependent water dosing
If the speed-dependent water dosing is switched on, the
brush watering changes proportionally with the speed.
The water dosage is additionally influenced by the setting
of the respective cleaning program (0...100%).
Setting
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Set speed-dependent or constant water dosing:
1. Turn the info button until "water dosage mode" is shown
in the display.
2. Press the info button.
3. Turn the info button until the desired function is
marked...
4. Press the info button.
1. Turn the info button until the menu item "delay times" is
shown in the display.
2. Press the info button.
3. Turn the info button until the desired assembly is
marked.
4. Press the info button.
5. Turn the info button until the desired after-running time
is displayed.
6. Press the info button.
1. Turn the info button until the menu item "language" is
shown in the display.
2. Press the info button.
3. Turn the info button until the desired language is
marked.
4. Press the info button.
English
2
ON [ml/m
]
OFF [l/min]
0
0
7.5
0.6
15
1.1
22.5
1.7
30
2.3
37.5
2.8
45
3.4
52.5
3.9
60
4.5
67.5
5.1
75
5.7
After-running times
Set language